AOT SWS06 sample time-line



next up previous contents index
Next: Observing Parameters AOT Up: AOT SWS06: Grating Previous: Description

AOT SWS06 sample time-line

1. Acquisition - point aperture 1 to target ( 3 min)
2. Dark current measurement (16 sec)
3. Reference scan near 12 m (16 sec)
4. Scan up around 12 m (24 sec, fast)
5. Scan down around 12 m (24 sec, fast)
6. Reference scan near 12 m (16 sec)
7. Dark current measurement (16 sec)
8. Switch to aperture 3 (10 sec)
9. Reference scans near 10 m and 33 m (16 sec)
10. Scans around 10 m and 33 m, up (360 sec)
11. Repeat 10
12. Scans around 10 m and 33 m, up, continued (360 sec)
13. Repeat 10
14. Scans around 10 m and 33 m, down (360 sec)
15. Repeat 10
16. Scans around 10 m and 33 m, down, continued (360 sec)
17. Repeat 10
18. Dark current measurement (16 sec)
19. Dark current measurement (16 sec)
20. Reference scans near 10 m and 40 m (16 sec)
21. Scans around 10 m and 40 m, up (96 sec)
22. Scans around 10 m and 40 m, down (96 sec)
23. Repeat 21
24. Dark current measurement (16 sec)
25. Internal photometric calibration (20 sec)
26. Internal calibrations (20 sec)